HP Alerts!

Description: When installing the Linux ClearOS operating system, Intelligent Provisioning 2.60 (or later) is supported.

 

Description: After a server's Integrated Lights-Out (iLO) address has been changed, HPE OneView 2.0 will fail to reconnect to it and the following error message will display in the OneView GUI:

 

Description: Hosts connected to HPE StoreVirtual 4000 or HPE StoreVirtual 3000 Storage systems may experience degraded performance and connectivity issues when running VMware ESXi 5.5 Update 2 or later with the ATS Heartbeat feature enabled. VMware ESXi 5.5 Update 2 introduced the ATS Heartbeat, a new method for managing the heartbeat process. This feature is not compatible with HPE StoreVirtual Storage systems.

 

Description: In rare instances, the message, "Drive Array Controller Failure" may be displayed in the Integrated Management Log (IML) on a ProLiant server configured with a Smart Array Px3X, Smart Array Px4x, or H24x controller.

 

Description: On an HPE ProLiant Gen8 or HPE ProLiant Gen9 server running Microsoft Windows Server 2012 or Microsoft Windows Server 2016 and configured with HPE Smart Array H240, H240ar, H241, H244br, P440ar, P440, P441, P840, P840ar, or P841 controllers and with any tape drive connected to those controllers, the Device Manager will display the Tape Device twice in the Device Manager.

 

Description: In HPE c-Class server blade enclosures with Onboard Administrator (OA) modules running firmware version 4.60 and managed by HPE OneView, a reset of the enclosure's primary OA module (or a failover from the primary OA module to the standby) will result in a power on delay of any server blade that is powered off and has a profile applied in the same enclosure as the OA.

 

Description: HPE StoreVirtual 4000 and HPE P4000 G2 Storage products, and HPE StoreVirtual VSA and HPE LeftHand P4000 Virtual SAN Appliance Software products running Multipathing Extension Module (MEM) versions 12.0 or 12.6.0.14 may experience the Purple Screen of Death (PSOD).

 

Description: On an HPE ProLiant Gen9 server configured with Smart Array Controller Firmware Version 4.02 (or later), the presence of non-HPE branded drive carriers will be detected by causing limited LED activity and displaying the following POST message:

 

Description: On an HPE ProLiant Gen9 server configured with Smart Array Controller Firmware Version 4.02 (or later), the presence of non-HPE branded drive carriers will be detected by causing limited LED activity and displaying the following POST message:

 

Description: On an HPE ProLiant server configured with any of the network adapters listed in the Scope section below, and running Microsoft Windows Server 2008, Microsoft Windows Server 2008 R2, Microsoft Windows Server 2012 or Microsoft Windows Server 2012 R2 configured as a domain controller, when a driver update is run (either manually or via a Smart Component) to the driver version 10.7.110.16 (or earlier), the update may either not run, or may appear to run but not complete.

 

Description: Any HP ProLiant ML/BL/DL Gen8-series server running a VMware ESXi 5.1, VMware ESXi 5.5 or VMware ESXi 6.0 host may experience either or both of the following:

 

Description: When applying or removing a Virtual Connect Server Profile to an HPE ProLiant Gen9 server blade, the Environment Variables CQHVUUID and CQHVSN, if present, are temporarily destroyed and re-created, even if a virtual serial number is not set in the Server Profile.

 